Shrimp and Fish Pond Pump Selection Guide: Flow, Head and Pond Size

A pump that works well beside a small fish pond can struggle on a larger shrimp farm, even when the motor rating looks generous. The usual problem is a mismatch between the flow needed at the pond and the head needed to push water through the installed pipework.

Start with a required duty point, expressed as cubic metres per hour at metres of total dynamic head. Then compare the model curve, wetted materials, electrical supply and permitted operating schedule. This guide uses the WS, WL and WLT catalogues and the FUTI Seawater Type Floating Pump data to show how that process works.

1. Calculate how much water must move

Pond area alone is not enough. A deep pond holds more water than a shallow pond of the same area, and draining a pond for harvest is a different duty from replacing part of its water.

Pond volume V (m³) = surface area (m²) × average water depth (m).
Required flow Q (m³/h) = volume to transfer (m³) ÷ available pumping time (hours).
For partial exchange: Q = pond volume × exchange fraction ÷ pumping time. One hectare equals 10,000 m²; 1 m³/min equals 60 m³/h.

For example, a 1-hectare pond averaging 1.5 m deep holds about 15,000 m³. Moving 10% of that volume in six hours requires 250 m³/h at the actual installation head. Emptying the same pond in six hours would require about 2,500 m³/h before allowing for falling water levels, sediment or residual water.

The 10% exchange figures below are sizing examples, not prescribed daily exchange rates. Set the actual transfer volume from your culture system, biosecurity plan, water quality, discharge rules and available water. A low-exchange shrimp system may need very different pumping capacity from a flow-through fish farm.

To plan the transfer volume before selecting equipment, see our practical guide to water exchange in aquaculture. For a new pond, our pond size and depth guide can help you establish the water volume used in the calculation.

For an open pond-to-reservoir transfer, begin with the difference between the source and receiving water levels. Add losses in the pipe, elbows, valves, screens and treatment equipment. Include outlet velocity head for a free discharge where applicable, or delivery pressure if the destination is pressurized.

TDH = static level difference + pipe friction + fitting and screen losses + other required head. Pond depth is not automatically the static lift. Use the lowest expected source level and the highest receiving level to check the demanding part of the cycle.

A practical pipe-size comparison

Consider 250 m³/h through 100 m of straight pipe, with a 2 m static lift. For illustration, take a Darcy friction factor of 0.02 and a combined fitting-loss coefficient K = 3. Treat the pipe sizes below as actual internal diameters, not nominal outside diameters. This calculation excludes intake-screen and treatment losses and treats the delivery as entering a receiving reservoir.

Illustrative head calculation at 250 m³/h
Internal pipe diameter Water velocity Straight-pipe loss Fitting loss Example TDH
200 mm 2.21 m/s 2.49 m 0.75 m 5.24 m
250 mm 1.41 m/s 0.82 m 0.31 m 3.12 m

The larger pipe lowers the example TDH from roughly 5.24 m to 3.12 m. That difference can be more useful than buying a larger motor. Check a WL-250-class pump against both points: the larger pipe allows a different operating point and may deliver more water with the same pump. Recalculate losses for the flow where the pump and system curves actually intersect.

3. Compare the four pump families

Pump-family comparison for pond water transfer
Family Performance data supplied Best starting application Selection check
WS amphibious pump 30–60 m³/h at paired rated heads of 8–12 m Smaller transfers or higher-head water delivery Land installation still requires correct suction, priming and water cooling
WL drainage pump 120–510 m³/h at paired rated heads of 3–6 m Higher-volume transfers at comparatively low head Check the chosen curve, solids, full materials list and duty rating
WLT drainage pump Same listed rated points as the corresponding WL models Large-flow supply and drainage where its materials suit the water Wetted internal materials differ from the WL catalogue
FUTI PS seawater floating pump Separate maximum head and maximum flow figures Mobile or surface-following water intake for suitable seawater installations Obtain a model-specific curve at the required head; maxima are not a duty point

WS models for smaller-volume, higher-head duties

WS catalogue paired rated points; listed models are three-phase
Model Power Outlet Rated flow Rated head
WS-0203 1.5 kW 80 mm / 3 in 30 m³/h 8 m
WS-0303 2.2 kW 80 mm / 3 in 36 m³/h 10 m
WS-0304 2.2 kW 100 mm / 4 in 48 m³/h 10 m
WS-0504 3.7 kW 100 mm / 4 in 60 m³/h 12 m

The WS-0303 and WS-0304 share a 2.2 kW motor rating but have different outlet sizes and rated flows at 10 m head. That is a useful reminder: kilowatts do not tell you how much water the pump will deliver. Compare the curves and connections. See our WS amphibious water pump range.

WS amphibious water pump range with stainless steel housings
WS pump range from the website media library.

WL and WLT models for larger, low-head transfers

Paired rated points listed in the WL and WLT brochures
WL / WLT model suffix Power Outlet Rated flow Rated head Listed solids passage
63 2.2 kW 150 mm / 6 in 120 m³/h 3 m 20 mm
150 3.7 kW 150 mm / 6 in 120 m³/h 5 m 20 mm
200 5.5 kW 200 mm / 8 in 210 m³/h 4 m 22 mm
250 7.5 kW 250 mm / 10 in 330 m³/h 4 m 23 mm
300 11 kW 300 mm / 12 in 420 m³/h 5 m 23 mm
1220 15 kW 300 mm / 12 in 510 m³/h 6 m 23 mm

Read suffix 250 as WL-250 or WLT-250, for example. The catalogues list the same hydraulic points for corresponding models; they do not establish that one series is inherently more efficient. WL-63 and WL-150 both list 120 m³/h, but at 3 m and 5 m head respectively. The higher-power version earns its place when the system needs more head, rather than automatically moving more water at every installation.

The catalogue describes centrifugal impellers for the 3 and 5 HP versions, axial-flow impellers for 7.5 and 10 HP, and mixed-flow impellers for 15 and 20 HP. Stay within the model’s approved operating envelope. See our large-flow drainage pump range.

FUTI Seawater Type Floating Pump

FUTI seawater floating-pump catalogue maxima; head and flow are separate endpoints
Model Listed power Maximum head Maximum flow Outlet Weight
PS-100 2.5 kW 9 m 100 m³/h 100 mm / 4 in 24 kg
PS-150 3.7 kW 10 m 170 m³/h 150 mm / 6 in 26 kg
PS-200 6.5 kW 10 m 260 m³/h 200 mm / 8 in 45 kg

The floating arrangement follows changes in water level and keeps the intake away from bottom sediment when correctly located and anchored. This can be useful for shrimp-farm reservoirs and pond-to-pond transfers. It does not remove discharge-pipe friction, fouling, water-quality or screening requirements.

The website separately lists a PS-150 60 Hz version at 4.0 kW, 11 m maximum head and 190 m³/h maximum flow. Do not mix those figures with the 50 Hz PS-150 values. Confirm the exact model and frequency when requesting its curve. Explore the FUTI PS floating irrigation and drainage pump.

FUTI floating pump used for irrigation and water transfer
Floating-pump water-transfer application from the media library.

4. Use curves to check the duty point

On an H–Q curve, head is on the vertical axis and flow is on the horizontal axis. Locate the required flow, move vertically to the selected pump curve, and read the head. The curve must provide the required head at that flow. The installed operating point is the intersection of the pump curve and the system curve.

Original WL catalogue head-flow curves for WL-63, WL-150, WL-200, WL-250, WL-300 and WL-1220
WL head-flow curves reproduced from the supplied English catalogue. Click to enlarge. Values read from the printed graph are approximate; some WLT graph labels use “WTL”.
Original WLT catalogue head-flow curves for six large-flow drainage pump models
WLT head-flow curves reproduced from the supplied English catalogue. Click to enlarge. Values read from the printed graph are approximate; some WLT graph labels use “WTL”.

A specific WL-250 example: the table lists 330 m³/h at 4 m. Its printed curve spans roughly 5–6 m around 240–300 m³/h and approaches 2.7–3 m near 420 m³/h. A system needing 250 m³/h at 6.5 m lies above that displayed curve. Lower the resistance or compare a different model. The graph and rounded table point are not identical at every reading; obtain the exact tested curve for the ordered configuration rather than using the image as a precision performance guarantee.

Head-flow performance curves for WS-0203, WS-0303, WS-0304 and WS-0504
WS catalogue curves from the existing media library: compare head at the required flow, not motor power alone.

The WS curves cover smaller flows at higher heads than the WL/WLT family shown here. A pond needing around 40 m³/h at 8–10 m total head calls for a different shortlist from one needing 300 m³/h at 4 m. Before comparing curves, verify the test frequency, impeller configuration and units. The brochures mention 50/60 Hz availability; use the curve supplied for the exact ordered version.

FUTI floating pump H-Q, efficiency-flow and power-flow reference curves
FUTI floating-pump reference graphic from the media library. The supplied graphic does not identify a separate H–Q curve for each PS model.

Use H–Q for delivery head, E–Q for efficiency and P–Q for power demand, checking the legend and units. The PS reference graphic is useful for understanding these relationships, but it is not enough to certify a PS-100, PS-150 or PS-200 at a particular duty. Request the identified model curve. A PS-150 maximum of 170 m³/h is not a promise of 170 m³/h at 10 m head.

5. Build a shortlist by pond size

The table below uses five illustrative pond sizes. TDH values are assumed design duties to demonstrate selection; calculate them from your own pipework. Each listed model is a candidate for a curve check, not a guaranteed site flow. Recheck the operating point, allowable flow range, electrical load and duty rating before ordering.

Worked sizing examples for small ponds through multi-pond farms
Pond area and average depth Example transfer duty Required flow Assumed TDH Initial shortlist
0.2 ha × 1.2 m 10% in 6 h: 240 m³ 40 m³/h 8 m WS-0304; compare its curve and minimum operating flow
0.5 ha × 1.5 m 10% in 8 h: 750 m³ 93.75 m³/h 3 m WL-63 / WLT-63 at the listed 120 m³/h, 3 m point
1 ha × 1.5 m 10% in 6 h: 1,500 m³ 250 m³/h 4 m WL-250 / WLT-250; listed 330 m³/h at 4 m
2 ha × 1.5 m 10% in 8 h: 3,000 m³ 375 m³/h 5 m WL-300 / WLT-300; listed 420 m³/h at 5 m
5 ha × 1.5 m 10% in 6 h: 7,500 m³ 1,250 m³/h 6 m Engineered multi-pump station; assess three 1220-series duty pumps plus standby capacity

Small fish pond: choose for the lift, not the acreage

The 0.2-hectare example needs 40 m³/h. WS-0304 is a reasonable first curve to examine because its rated point is 48 m³/h at 10 m. A low-head drainage pump selected only for a large flow figure may not reach the installation head. If the actual lift is much lower, compare a smaller pump or a suitable floating pump rather than keeping an oversized unit.

Medium shrimp pond: floating or fixed intake?

For the 0.5-hectare example, WL-63/WLT-63 provide a known catalogue point above the calculated 93.75 m³/h at 3 m. For saline water with a mobile intake, PS-150 is a sensible model to ask about, but obtain confirmation that it can supply at least 93.75 m³/h at the complete TDH. PS-100’s 100 m³/h maximum leaves almost no margin even before head reduces flow; it should not be assumed adequate.

Larger ponds: protect the flow with large pipework

The 1-hectare example moves 1,500 m³ in six hours. Start with the 250-series curve and an appropriately sized delivery line. At 250 m³/h, a small pipe can consume several metres of head. For the 2-hectare example, compare the 300-series curve at the calculated TDH, then check the lowest source level and a partially fouled intake screen.

Multi-pond farm: calculate the parallel system

Three 1220-series pumps have a catalogue sum of 1,530 m³/h at the listed 6 m point. That is only an initial screening calculation. Shared headers, individual branch losses and rising system resistance determine the actual combined flow, so adding a second pump does not necessarily double delivery. Consider duty/standby arrangements, independent isolation, non-return protection and a control plan for changing demand.

6. Match materials to freshwater, brackish water or seawater

Material differences visible in the supplied WL and WLT specifications
Component listed in the catalogues WL WLT Why it matters
Outer housing / motor frame Stainless steel Stainless steel Outer appearance does not identify every wetted part
Impeller Bronze Bronze Both series list bronze impellers
Top cover Bronze Cast iron Different corrosion exposure in saline water
Seal housing and bearing base Bronze Cast iron Confirm which parts are exposed to the pumped liquid
Cover / casing component Cast iron Cast iron Check coating, corrosion allowance and exact configuration

For freshwater drainage, WLT may be considered where its full material specification and water chemistry are suitable. For brackish or seawater shrimp ponds, begin with the intended FUTI Seawater Type Floating Pump configuration or request a verified saline-water configuration for WL/WS. Neither an IP68 rating nor a stainless steel exterior proves that the complete pump is corrosion-resistant in seawater.

Send the salinity, temperature, pH, expected sand content and treatment chemicals. Ask for the impeller, casing, shaft, fastener and seal materials, not just the housing grade. The WS catalogue includes coated HT200 cast-iron components alongside stainless steel and bronze parts. It should not be treated as an all-stainless seawater pump.

7. Check operating limits before specifying long daily runs

The supplied general instruction manual says no more than eight operating hours per day, advises against 24-hour continuous running, and limits starts to ten per hour. The WL/WLT and WS brochures describe long-running water-cooled designs. Those statements are not sufficiently consistent to establish unrestricted continuous-duty operation.

For a daily schedule beyond eight hours, obtain the model-specific operating limit in writing or select a separately confirmed continuous-duty pump. Alternating units can meet a longer system schedule only when each unit remains within its approved daily and start-frequency limits. Do not assume that a timer or additional cooling overrides the manual.

  • Electrical supply: verify voltage, phase, frequency, starting current, controller and overload protection. The general manual gives a voltage tolerance of ±10%; the exact nameplate remains controlling.
  • Installation: use qualified electrical personnel, protective earthing and suitable earth-leakage protection. Keep cable terminals dry and lift using the lifting points, not the power cable.
  • WS land use: establish a sealed, correctly primed suction arrangement and maintain water flow for cooling. “Amphibious” does not mean dry-running. The brochure’s approximate 8 m suction claim is not a guaranteed installation allowance; check NPSH and source conditions.
  • Temperature: WS catalogue data lists 1–40°C; WL/WLT data lists 0–40°C. Confirm the exact unit’s permitted range.
  • Solids and screens: WL/WLT list 20–23 mm solids passage. That is not permission to pass nets, long fibres, heavy sludge or live fish. Keep fish and shrimp away from the intake with appropriately designed screens, allowing for screen head loss.
  • Commissioning: confirm rotation direction, then measure delivered flow, head, current, noise and vibration. Low flow can indicate reversed rotation, an obstructed intake, air, a closed valve or underestimated resistance.

8. Compare electricity per cubic metre

Compare measured electrical input at the chosen operating point, not nameplate motor power divided by maximum catalogue flow. Use specific energy = measured input power (kW) ÷ delivered flow (m³/h). For illustration, 4 kW supplying 100 m³/h uses 0.04 kWh/m³; moving 1,500 m³ would consume about 60 kWh before other loads. This is a calculation example, not a tested result for any model in the table.

A lower-head installation, a correctly sized pipe and a pump running near an approved efficient duty can reduce energy per unit volume. Request power and efficiency data for the actual duty point, especially when comparing a floating pump with a fixed submersible installation.

Frequently Asked Questions

What size pump do I need for a one-hectare shrimp pond?

At 1.5 m average depth, moving 10% in six hours requires 250 m³/h. If the calculated TDH is 4 m, investigate the WL-250/WLT-250 curve and material suitability. Different depths, exchange volumes, operating windows or pipe losses change the answer.

Can PS-200 deliver 260 m³/h at 10 m?

The supplied table gives maximum flow and maximum head separately. It does not establish 260 m³/h at 10 m. Obtain the identified PS-200 curve and select from the required operating point.

Are WL and WLT hydraulically interchangeable?

Their brochures list matching rated flow-head points for corresponding models, but internal materials differ. Confirm the exact curve, construction, test frequency and operating limits before substituting one for the other.

Is a water-transfer pump enough for pond aeration?

Water movement and oxygen-transfer capacity are different selection questions. Pump size for exchange does not establish sufficient dissolved-oxygen support for stocked biomass. Plan the pond’s aeration system separately; compare paddlewheel aerators where surface aeration and circulation are required.

Our aquaculture water quality management guide explains the water conditions to monitor alongside your pumping and aeration plan.

Send your pond duty for a model recommendation

For a useful quotation, send pond area and average depth, required transfer volume and time, source and destination levels, pipe internal diameter and length, fittings, salinity, solids conditions, voltage, phase, frequency and daily running schedule. Include the number of ponds served at the same time and the standby requirement.

Contact Mike Xia at tim@futi.com or WhatsApp +86 13291610116. A reservoir or pipe-layout sketch helps us compare the required duty with the correct model curve.

Previous
Pre-Stocking Aerator Commissioning Checklist: Is Your Pond Ready?
Next
Getting Started with the STFF-1500 360° Feeding Machine: A Practical Operation Guide
Recent Posts

How to Use a Secchi Disk to Measure Water Transparency

Paddlewheel Aerator Gearbox: Nylon vs Cast Iron for Saltwater Applications

Fordy / FUTI at Qingdao CFSE 2026: Paddlewheel and Impeller Aerators

Optical vs Membrane Dissolved Oxygen Meters: Which Is Better for Aquaculture?

Get Free Quote
Contact Us
Michael

Michael Huang
futi@futi.com
+86 13968610279

mike

Mike Xia
tim@futi.com
+86 13291610116

Get Free Quote