Know Your Water Before You Adjust Your Aeration
A dissolved oxygen reading gives you a practical starting point when checking pond conditions or reviewing an aeration routine. This portable optical dissolved oxygen meter puts DO, temperature and saved-reading information on one clear display, so you can move between sampling points with a compact handheld instrument.
Designed for routine spot checks in aquaculture, hatcheries and water-treatment applications, it combines an optical probe with automatic temperature compensation and manually adjustable salinity and altitude settings. It is a useful companion to your aeration equipment when you want to record what is happening in the water.
Optical Sensing with Less Routine Probe Maintenance
The fluorescence-based probe measures dissolved oxygen without electrolyte refilling or the replaceable membrane sleeve used by conventional electrochemical probes. That means fewer routine consumable-handling steps during everyday checks. The optical sensing surface still needs proper cleaning, care and calibration checks; low maintenance does not mean maintenance-free.
Features That Fit a Daily Checking Routine
- DO and temperature together: read dissolved oxygen concentration and water temperature on the same screen, with a saturation percentage mode available.
- A backlit display: switch on the backlight when you need a clearer view in lower light.
- Compensation for your site: automatic temperature compensation works alongside manually entered salinity and altitude values.
- Save the readings you need: manually store up to 99 entries and recall them on the meter when reviewing your checks.
- A separate probe: the approximately 3.5 m assembly, including the probe, helps you reach the sampling point while keeping the handheld unit out of the water.
- Portable battery power: four AAA batteries make it convenient to carry between ponds and tanks.
Compensation Settings for Freshwater and Saline-Water Checks
Fresh water and saline water need different compensation settings. Enter the actual salinity of the sample water and the altitude of the site before using the meter, following the supplied instructions. The meter does not measure salinity or altitude automatically: these are user-entered compensation values.
When you are building a repeatable checking routine, note the sampling location, depth and time alongside the reading. This handheld meter is intended for spot measurements; it is not a continuous monitoring station or an automatic aerator controller.
Technical Specifications
| Parameter | Specification |
|---|---|
| Measurement method | Optical fluorescence dissolved oxygen sensing |
| Dissolved oxygen range | 0.0–20.0 mg/L |
| Oxygen saturation range | 0.0–199.9% |
| DO resolution | 0.1 mg/L |
| DO accuracy | ±3% FS (full scale) |
| Temperature range | 0.0–60.0 °C |
| Temperature resolution / accuracy | 0.1 °C / ±0.5 °C |
| Temperature units | °C / °F |
| Temperature compensation | Automatic (ATC) |
| Salinity compensation | 0–42 ppt, manually set |
| Altitude compensation | 0–3,500 m, manually set |
| Data memory | Up to 99 manually saved readings |
| Display | 41 × 50 mm LCD with backlight |
| Probe cable assembly length | Approximately 3.5 m, including probe |
| Power supply | 4 × 1.5 V AAA batteries |
| Meter dimensions | 70 × 35 × 167 mm |
FS means full scale. The stated ±3% FS accuracy is not the same as ±3% of an individual reading.
From Switching On to Saving a Reading
You do not need a complicated routine to get started, but giving the probe time to stabilize matters. Follow the supplied instructions and use this outline for a typical spot check:
- Install the batteries, connect the probe and switch on the meter. Check the battery indicator and the compensation settings.
- Allow the reading to stabilize in air for approximately 1–3 minutes, as described in the manual.
- Place the probe at the water depth you want to test, keeping it clear of the pond or tank bottom. Gently move the probe as instructed and allow approximately 2–3 minutes for the reading to stabilize.
- Read DO and temperature, then use SAVE if you want to store the result. Use the recall function to review saved entries.
- Rinse the probe with clean water after use, remove deposits carefully according to the supplied instructions and dry the equipment for storage.
Keep the handheld meter dry. Immerse the probe only. Do not treat the sealed housing as permission to submerge the instrument. Avoid contact with the bottom, impacts to the sensing head and freezing during storage.
Calibration and Care: Keep the Reading Useful
The meter supports air-saturation calibration. Follow the supplied procedure, including temperature stabilization and altitude entry, and verify the instrument as required for your measurement routine. A significant temperature change is a reason to check calibration rather than assuming an old setting still suits the new conditions.
Clean the probe after use and keep the sensing surface free from mud, algae and organic deposits. For extended storage, clean and dry the probe and cable, remove the batteries and store above 0 °C in a cool, ventilated place.
What Comes with the Meter?
The standard configuration listed in the supplied documentation includes the handheld meter, optical dissolved oxygen probe, screwdriver, instruction manual, inspection certificate, batteries, carrying case and outer carton. Confirm the shipment configuration when requesting a quotation, particularly any battery-shipping requirements.
Optical or Membrane: Which DO Meter Fits Your Routine?
Comparing sensor types before choosing a meter? Read our optical vs membrane dissolved oxygen meter guide for a practical comparison of sensing principles, electrolyte and membrane servicing, response time, calibration and ownership cost. It explains where optical fluorescence sensing can simplify daily checks and when a membrane probe may still suit your application.
Frequently Asked Questions
Does it measure both mg/L and oxygen saturation?
Yes. It offers dissolved oxygen concentration in mg/L and oxygen saturation in percentage, together with a temperature reading.
Does the probe need electrolyte refilling?
No. This optical version does not require electrolyte refilling. It still needs cleaning, careful handling and calibration checks in accordance with its instructions.
Can I download readings to a computer?
The documented function is manual storage and on-meter recall of up to 99 entries. Computer export, Bluetooth and cloud connectivity are not specified for this product.
Can I use it in saline water?
The salinity compensation setting covers 0–42 ppt. Enter the actual sample salinity and follow the probe’s supplied use and care instructions.
Add Water Checks to Your Pond Equipment Plan
Looking for a portable DO meter for your farm, hatchery or water-treatment team? Send us your application, typical water salinity, required quantity and delivery destination so we can discuss the configuration and quotation.
For a wider pond equipment plan, explore our paddlewheel aerators or browse aquaculture equipment. Use the enquiry form on this page to ask about this dissolved oxygen meter.





